HP StorageWorks XP Performance Advisor Software v4.6 Command-line User Interface Reference Guide (T1789-96095, June 2010)

C Sample outputs
This section identifies sample outputs of the most used commands.
NOTE:
Labels in labeled outputs (specified by –hr or –L in the command line) are in bold.
DKCS
dkcs -hr -dkc 10055
Array Type: XP 12000
Serial #: 10055
Record Time: 21:05:00
Record Date: 05/12/2010
Micro Code: 50-09-74/00
Raid Manager Lib: 01.14.02
Chip Data: ACP Data:
E = 0% 0% 0% 0% 0% 0% 0% 0% A = 16% 22% 16% 22% 16% 22% 16% 22%
F = 32% 31% 0% 0% 0% 1% 0% 0% B = 0% 0% 0% 0% 0% 0% 0% 0%
G = 0% 0% 0% 0% 0% 0% 0% 0% L = 0% 0% 0% 0% 0% 0% 0% 0%
H = 0% 0% 0% 0% 0% 0% 0% 0% K = 0% 0% 0% 0% 0% 0% 0% 0%
Q = 0% 0% 0% 0% 0% 0% 0% 0% M = 16% 22% 16% 22% 16% 22% 16% 22%
R = 0% 4% 0% 0% 1% 1% 0% 0% N = 0% 0% 0% 0% 0% 0% 0% 0%
T = 0% 0% 0% 0% 0% 0% 0% 0% X = 0% 0% 0% 0% 0% 0% 0% 0%
U = 0% 0% 0% 0% 0% 0% 0% 0% W = 0% 0% 0% 0% 0% 0% 0% 0%
A = 0% 0% 0% 0% 0% 0% 0% 0%
B = 0% 0% 0% 0% 0% 0% 0% 0%
L = 0% 0% 0% 0% 0% 0% 0% 0%
K = 0% 0% 0% 0% 0% 0% 0% 0%
M = 0% 0% 0% 0% 0% 0% 0% 0%
N = 0% 0% 0% 0% 0% 0% 0% 0%
X = 0% 0% 0% 0% 0% 0% 0% 0%
W = 0% 0% 0% 0% 0% 0% 0% 0%
SM Bus = 3% Cache Usage = 5772 MB
CM Bus = 0% Cache Size = 16384 MB
Cache Pending = 2 MB
Cache Side File = 0 MB
HP StorageWorks XP Performance Advisor Software Command-Line User Interface Reference
Guide 65