HP StorageWorks Performance Advisor XP Software user guide (T1789-96025, October 2007)
Component Description
Email Destination
Specify the pathname of the email destination where
you want to receive new alarm event information.
NOTE:
You must enter an email address for an alarm to
be active and to receive reports.
NOTE:
The most common email error is because the
SMTP server is not defined. For more information
about this feature, see the
HP StorageWorks
Performance Advisor XP Software installation
guide
. To verify SMTP server availability, enter
telnet smtpservername 25 at the command
prompt to get a connection. Enter QUIT to e x it .
Enable Alarm (checkbox)
Enables ala rms on the different metrics.
Fill from Top Selection Use the data from one alarm to create or modify
another alarm.
Script File (XML)
Enter the name of the batch file (in XML format) that
you want to execute, depending on the alarm type.
SNMP Destination
Specify the IP address of the SNMP Management
Station where you want to receive new alarm event
information. For more information about this feature,
HP StorageWorks Per formance Advisor XP Software
installation guide.
Threshold L
evels [1, 2, 3]
Designate the performance metric data value (1, 2,
or3)atwhichanalarmbecomesactive.Thehigher
the threshold level, the more critical the event.
NOTE:
When you change threshold levels, a ny new
events appear in the Event Log screen, which
showsthelevelandthetimewhentheeventwas
posted and updated.
HP StorageWorks Performance Advisor XP Software user guide
83