hp StorageWorks NAS e7000 v2 Maintenance and Service Guide
Removal and Replacement Procedures
68 NAS e7000 v2 Maintenance and Service Guide
SCSI Cables
To remove the SCSI cables:
1. Power down the server. Refer to “Powering Down the Server” in this chapter.
2. Extend the server from the rack. Refer to “Extending the Rack from the Server” in this
chapter.
3. Open the rear access panel. Refer to “Opening and Removing the Rear Access Panel” in
this chapter.
4. Remove the front access panel. Refer to “Removing the Front Access Panel” in this
chapter.
5. Disconnect the SCSI cables from the SCSI backplane (1).
6. Disconnect the SCSI cables from the PCI-X expansion boards (2).
Figure 44: Disconnecting SCSI cables from the backplane and expansion boards
Reverse steps 1 through 6 to replace or install the SCSI cables.
Front Fan Cage
To remove the front fan cage:
1. Power down the server. Refer to “Powering Down the Server” in this chapter.
2. Extend the server from the rack. Refer to “Extending the Rack from the Server” in this
chapter.
3. Remove the rear access panel. Refer to “Opening and Removing the Rear Access Panel”
in this chapter.
4. Remove the front access panel. Refer to “Removing the Front Access Panel” in this
chapter.
5. Remove the hot-plug fans in the front fan cage. Refer to “Hot-Plug Fans” in this chapter.
6. Remove the processor air baffle. Refer to “Processor Air Baffle” in this chapter.
7. Remove the memory boards. Refer to “Removing a Memory Board” in this chapter.
1
2