hp StorageWorks NAS e7000 v2 Maintenance and Service Guide
Removal and Replacement Procedures
47NAS e7000 v2 Maintenance and Service Guide
e. Press any key to return to the RBSU main menu.
f. Select System Options.
g. Select Advanced Memory Protection.
h. Select the desired memory mode.
i. Press the Esc key twice to go back to the main RBSU menu.
j. Press the F10 key to exit RBSU. The server reboots and tests all memory in the
system.
k. Once the memory has been tested, re-enable POST Speed Up for faster system boot, if
desired.
Note: To reconfigure the memory mode after initial setup, you must reboot the system and enter
RBSU.
Hot-Plug Procedures
You can perform removal and replacement procedures for some server components without
powering down the server. This section describes the removal and replacement procedures for
the following hot-plug components:
■ Hard drive blanks
■ Hot-plug SCSI hard drives
■ Power supply blank
■ Hot-plug power supplies (must have two power supplies installed for it to be hot-plug
capable)
■ PCI and PCI-X Hot Plug expansion boards (in hot-plug slots)
■ Hot-plug fans
■ Hot-plug mirrored memory boards (refer to “Memory” in this chapter)
Hard Drive Blanks
To remove a hard drive blank:
1. Push the sliding release button to unlock the blank (1).
2. Pull the drive blank out of the drive cage (2).