hp StorageWorks NAS e7000 v2 Maintenance and Service Guide
Connectors, LEDs, and Switches
104 NAS e7000 v2 Maintenance and Service Guide
Caution: After the server is powered down, wait 15 seconds and then check the LED
illumination pattern before unplugging the cable from the battery module. The LEDs are not
visible with the rear access panel on.
■ If the amber LED blinks after 15 seconds, do not remove the cable from the battery
module. This module is backing up data, and data is lost if the cable is detached.
■ If neither LED blinks after 15 seconds, it is safe to remove the cable from the battery
module.
When the server is on, review the POST message before plugging or unplugging the cable
from the module.
Memory Board
Figure 73 and Table 28 through Table 31 identify the memory board LEDs and their statuses
for specific memory modes.
Figure 73: Memory board LEDs
On-Line Spare
M
E
M
O
R
Y
S
T
A
T
U
S
2
8
7
6
5
4
3
1
A
B
Online Spare Status
Mirroring Status
Ready to Hot Plug
1
2
3
4
5
6
7 8
9
10
11
12
13