hp StorageWorks NAS e7000 v2 Maintenance and Service Guide

Connectors, LEDs, and Switches
103NAS e7000 v2 Maintenance and Service Guide
Battery-Backed Write Cache Enabler
When the battery-backed write cache (BBWC) enabler is connected to the controller and the
server is powered on, the green LED indicates the battery charge status. When the battery is
connected to the controller and the server is powered down, the amber LED indicates the data
retention status. Figure 72 and Table 27 identify the location and status of the LEDs.
Figure 72: Battery-backed write cache enabler LEDs
Note: The battery will take 24 hours to charge for the first time.
Table 27: Battery-Backed Write Cache Enabler LEDs
Server Status LED Color LED Status Battery Module Status
Server is on and has
normal run time.
Green On Fast charging
Green Off Trickle charging
Amber On Short in the connection of one
or more of the four button cells
within the battery module
Amber Blinking Open in the circuit between the
positive and negative terminals
of the battery module
Server is on and is in the
first 30 seconds after
power up.
Amber or
green
On Temporary lock-out state; data
is lost due to cable being
detached
Server is off and is in data
retention mode.
Amber Blinking every
15 seconds
User data held in write cache is
being backed up
1
2