HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)
XPath OS 7.4.x system error messages reference guide 99
Recommended action
Reboot or power cycle the MP Router.
Severity
Critical
SWAL-CSCN_TX_FAILURE
Message
Probable cause
A CSCN transmit failure occurred. There might be a CSCN connection problem.
Recommended action
Reboot or power cycle the MP Router.
Severity
Critical
SWAL-FCR_API_CSCN, Error sending data
Message
Probable cause
An error occurred trying to send information to the iswitchd daemon. Typically, this problem is resolved
without user intervention. It can be ignored unless seen repeatedly.
Recommended action
Wait a few minutes and retry the operation. Reboot or power cycle the MP Router.
Severity
Warning
SWAL-FCR_API_CSCN, Error receiving data
Message
Probable cause
An error occurred trying to send information to the iswitchd daemon. Typically, this problem is resolved
without user intervention. It can be ignored unless seen repeatedly.
process_id (module_name): date time
Critical SWAL-CSCN_TX_FAILURE, 1, Fail to send for process function_name
file_name line_number
process_id (module_name): date time
Warning SWAL-FCR_API_CSCN, 3, Error sending data to FCR
process_id (module_name): date time
Warning SWAL-FCR_API_CSCN, 3, Error receiving data from FCR