HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)

88 Error messages
FCR-ISWFAB (malloc failed)
Message
Probable cause
A memory allocation failed. The system is low on memory or has a memory leak. The value is either a
configuration, a zone, or an alias name.
Recommended action
If the problem persists, reboot the switch.
Severity
Warning
FCR-ISWFAB (group slots)
Message
Probable cause
The slots available for storing zoning information are filled to capacity.
Recommended action
Reduce the size of the zone database in the edge fabric by deleting all unused aliases, zones, and
configurations.
Severity
Warning
FCR-ISW_ZN
Message
Probable cause
The number of devices per LSAN zone exceeds the limit.
Recommended action
Reduce the size of the LSAN zone in the zone database of the edge fabric to be within the limit, by
removing the unused zone members.
Severity
Warning
process_id (iswitchd): date time
Warning FCR-ISWFAB, 3, isw: malloc failed for value
process_id (iswitchd): date time
Warning FCR-ISWFAB, 3, ran out of available group slots
process_id (iswitchd): date time
Warning FCR-ISW_ZN, 3, mem_num devices in lsanzone lsan_zone_name greater than the
limit MAX_DEV_PER_LSAN_ZONE