HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)

80 Error messages
Recommended action
1. Use the top command to look for a memory leak.
The top command displays memory usage on the switch and the daemons running. Most daemons
should show approximately 1 MB. The nsd daemon typically shows 30 MB. If any daemon is running
up to 10 MB or the nsd daemon shows above 50 MB, then there might be memory leak.
2. Check the last value in the memory line of the top command output for system free space.
This value varies, depending on configuration, but should be approximately 800 MB free. A memory
leak usually indicates a problem with the XPath OS.
3. Contact your switch supplier for an updated version of the XPath OS. Use the firmwareDownload
command to update the firmware.
Severity
Error
DIAG-MSG_SEND_FAIL
Message
Probable cause
A CSCN transmit failure occurred. This might be a CSCN connection problem.
Recommended action
Reboot or power cycle the MP Router.
Severity
Error
DIAG-SYSAPI_FAIL
Message
Probable cause
An error was reported to the API.
Recommended action
Reboot or power cycle the MP Router.
Severity
Error
process_id (diagd): date time
Error DIAG-MSG_SEND_FAIL, 2, function_name:sb_send() failed
process_id (diagd): date time
Error DIAG-SYSAPI_FAIL, 2, function_name:cscn-api-name failed