HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)

72 Error messages
Recommended action
1. Reboot or power cycle the MP Router.
2. If the problem persists, run the firmwareDownload command to upgrade the firmware.
Severity
Error
CM-ZONE_DB_FAIL_18
Message
Probable cause
The zone database file does not exist or was not found.
Recommended action
1. Reboot or power cycle the MP Router.
2. If the problem persists, run the firmwareDownload command to upgrade the firmware.
Severity
Error
CM-ZONE_DB_FAIL_19
Message
Probable cause
The zone database file was not found or has an mmap error.
Recommended action
1. Reboot or power cycle the MP Router.
2. If the problem persists, run the firmwareDownload command to upgrade the firmware.
Severity
Error
process_id (EvtMgr): date time
Error CM-ZONE_DB_FAIL_18, 2, Failed to open file(file_name) function_name
process_id (EvtMgr): date time
Error CM-ZONE_DB_FAIL_19, 2, mmap failed function_name