HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)

XPath OS 7.4.x system error messages reference guide 63
Recommended action
No action is required.
Severity
Info
CM-EVENT_WARNING_TEMP_EXCEEDED
Message
Probable cause
The warning temperature limit has been exceeded. The fan speed is automatically increased. Temperature
problems usually indicate problems with fans or the environment temperature.
Recommended action
1. Use the tempShow command to view the temperature of the MP Router.
2. Use the fanShow command to verify that the fans are operating properly.
3. Replace any defective fan FRUs.
4. Verify that the room temperature is within the operational range.
See the installation guide for your switch for details about the operational temperature range.
Severity
Warning
CM-EVENT_WARNING_TEMP_EXCEEDED_CLEAR
Message
Probable cause
The warning temperature limit has been cleared. Temperature problems usually indicate problems with
fans or the environment temperature.
Recommended action
No action is required.
Severity
Info
process_id (EvtMgr): date time
Warning CM-EVENT_WARNING_TEMP_EXCEEDED, 3, Warning temperature exceeded, card n
sensor s temp t
process_id (EvtMgr): date time
Info CM-EVENT_WARNING_TEMP_EXCEEDED_CLEAR, 4, Warning temperature exceeded clear,
card n sensor s temp t