HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)
XPath OS 7.4.x system error messages reference guide 57
CM-EVENT_POWER_DOWN
Message
Probable cause
Power supply n is down, where n represents either power supply 1 or 2.
Recommended action
1. Check the power supply status using the chassisShow command.
2. Try reseating the specified power supply.
3. If the problem persists, replace the failed power supply.
Severity
Warning
CM-EVENT_POWER_INSERT
Message
Probable cause
Power supply n was inserted, where n represents either power supply 1 or 2.
Recommended action
No action is required.
Severity
Info
CM-EVENT_POWER_REMOVE
Message
Probable cause
Power supply n was removed, where n represents either power supply 1 or 2.
Recommended action
1. Check the power supply status using the chassisShow command.
2. If the power supply is still in the chassis, try reseating the specified power supply.
3. If the power supply is removed from the chassis (due to failure), replace it with a new power supply
FRU.
Severity
Warning
process_id (EvtMgr): date time
Warning CM-EVENT_POWER_DOWN, 3, Power n down
process_id (EvtMgr): date time
Info CM-EVENT_POWER_INSERT, 4, Power n inserted
process_id (EvtMgr): date time
Warning CM-EVENT_POWER_REMOVE, 3, Power n removed