HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)
54 Error messages
CM-EVENT_PORT_ERROR
Message
Probable cause
An invalid full loop configuration was initiated or a port driver failed.
Recommended action
1. Check the port configuration using the portCfgGige command or Advanced Web Tools.
2. Remove extra devices from the loop.
If the error is due to a port driver failure, the system restarts the port.
Severity
Error
CM-EVENT_PORT_ICMP_ERROR
Message
Probable cause
One of the following port ICMP errors has occurred on port n:
• Network unreachable
• Host unreachable
• Protocol unreachable
• Port unreachable
• Fragmentation needed but don't-fragment bit set
• Source route failed
• Destination network unknown
• Destination host unknown
• Source host isolated
• Destination network administratively prohibited
• Destination host administratively prohibited
• Network unreachable for TOS
• Host unreachable for TOS
• Communication administratively prohibited by filtering
• Host precedence violation
• Precedence cutoff in effect
• Redirect for network
• Redirect for host
• Redirect for type-of-service and network
• Redirect for type-of-service and host
• Time-to-live equals 0 during transit
• Time-to-live equals 0 during reassembly
process_id (EvtMgr): date time
Error CM-EVENT_PORT_ERROR, 2, Port error
process_id (EvtMgr): date time
Warning CM-EVENT_PORT_ICMP_ERROR, 3, Port ICMP error