HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)

54 Error messages
CM-EVENT_PORT_ERROR
Message
Probable cause
An invalid full loop configuration was initiated or a port driver failed.
Recommended action
1. Check the port configuration using the portCfgGige command or Advanced Web Tools.
2. Remove extra devices from the loop.
If the error is due to a port driver failure, the system restarts the port.
Severity
Error
CM-EVENT_PORT_ICMP_ERROR
Message
Probable cause
One of the following port ICMP errors has occurred on port n:
Network unreachable
Host unreachable
Protocol unreachable
Port unreachable
Fragmentation needed but don't-fragment bit set
Source route failed
Destination network unknown
Destination host unknown
Source host isolated
Destination network administratively prohibited
Destination host administratively prohibited
Network unreachable for TOS
Host unreachable for TOS
Communication administratively prohibited by filtering
Host precedence violation
Precedence cutoff in effect
Redirect for network
Redirect for host
Redirect for type-of-service and network
Redirect for type-of-service and host
Time-to-live equals 0 during transit
Time-to-live equals 0 during reassembly
process_id (EvtMgr): date time
Error CM-EVENT_PORT_ERROR, 2, Port error
process_id (EvtMgr): date time
Warning CM-EVENT_PORT_ICMP_ERROR, 3, Port ICMP error