HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)
50 Error messages
CM-EVENT_ISCSI_LOGIN_FAILED
Message
Probable cause
An iSCSI initiator failed to successfully negotiate operational parameters with the target.
Recommended action
Check the list of parameters negotiated from the initiator. Look at the /var/log/messages file for the
exact parameter that the switch expected but did not get from the initiator.
Severity
Error
CM-EVENT_ISCSI_LOGIN_SUCCESS
Message
Probable cause
An iSCSI initiator successfully logged in to a target.
Recommended action
No action is required.
Severity
Info
CM-EVENT_ISCSI_SESSION_ABORTED
Message
Probable cause
An active session between an initiator and a target was aborted due to a connectivity failure.
Recommended action
Check connectivity and availability of the initiator and target.
Severity
Error
process_id (EvtMgr): date time
Error CM-EVENT_ISCSI_LOGIN_FAILED, 2, iSCSI login failed: login_level
process_id (EvtMgr): date time
Info CM-EVENT_ISCSI_LOGIN_SUCCESS, 4, iSCSI login: login_level
process_id (EvtMgr): date time
Error CM-EVENT_ISCSI_SESSION_ABORTED, 2, iSCSI session aborted: session_id