HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)
42 Error messages
Recommended action
No action is required.
Severity
Info
CM-EVENT_FCR_NEW_NR_PORT_ADDED
Message
Probable cause
An NR_Port was created at port n on domain domID.
Recommended action
No action is required.
Severity
Info
CM-EVENT_FCR_NODE_WWN_POOL_FULL
Message
Probable cause
The node WWN pool is close to rollover, and the WWN entries not in use are reused as needed.
Recommended action
It is unlikely that WWN conflicts occur as a result of pool rollover unless the FCR is deployed in a very
large meta-SAN environment with a large number of LSAN devices and fabrics, or there are highly
dynamic changes to EX_Port connectivity. WWN conflicts might cause unpredictable behavior in
management applications. To avoid WWN conflicts, all EX_Ports attached to fabrics with highly dynamic
changes to EX_Port connectivity should be disabled then re-enabled.
Severity
Info
process_id (EvtMgr): date time
Info CM-EVENT_FCR_NEW_NR_PORT_ADDED, 4, FCR new NR_Port added at port n domain_id
domID
process_id (EvtMgr): date time
Info CM-EVENT_FCR_NODE_WWN_POOL_FULL, 4, FCR node wwn pool 95% allocated