HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)
XPath OS 7.4.x system error messages reference guide 37
Recommended action
No action is required.
Severity
Info
CM-EVENT_FCR_ISWFAB (malloc)
Message
Probable cause
A memory allocation failed. The system is low on memory, and possibly has a memory leak. The value is
either a cfg, zone, or alias_name.
Recommended action
If the problem persists, reboot the switch.
Severity
Warning
CM-EVENT_FCR_ISWFAB (group slots)
Message
Probable cause
The slots available for storing zoning information are filled to capacity.
Recommended action
Reduce the size of the zone database in the edge fabric. This task can be accomplished by deleting all
unused aliases, zones, and configurations.
Severity
Warning
CM-EVENT_FCR_LOCAL_LSAN_DEVICE_ENTRY_EXHAUSTED
Message
Probable cause
The number of devices created through logical storage area network (LSAN) zones within the meta-SAN is
greater than the LSAN zone database limitations of the local Fibre Channel Router (FCR).
process_id (EvtMgr): date time
Warning CM-EVENT_FCR_ISWFAB, 3, isw: malloc failed for value
process_id (EvtMgr): date time
Warning CM-EVENT_FCR_ISWFAB, 3, ran out of available group slots
process_id (EvtMgr): date time
Warning CM-EVENT_FCR_LOCAL_LSAN_DEVICE_ENTRY_EXHAUSTED, 3, FCR local LSAN device
entries exhausted