HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)

XPath OS 7.4.x system error messages reference guide 35
CM-EVENT_FCIP_TUNNEL_UP
Message
Probable cause
FCIP tunnel n is up due to:
A switch reboot
An administrator enabling the FCIP tunnel
Recommended action
No action is required.
Severity
Info
CM-EVENT_FCIP_WWN_MISMATCH
Message
Probable cause
An FCIP tunnel cannot be established because the world-wide name (WWN) on the remote side does not
match the security-restricted local WWN.
Recommended action
1. Check the FCIP configuration using the portCfgFcip command on the remote side.
2. Issue the switchShow command on the local side to get the local switch WWN.
3. Correct the remote FCIP configuration WWN to match the local switch WWN.
4. Check the FCIP configuration WWN on the local switch, and match the WWN with that of the remote
switch.
Severity
Error
CM-EVENT_FCR_EX_PORT_FABRIC_DONE
Message
Probable cause
An FCR EX_Port fabric has completed a fabric build at port n.
process_id (EvtMgr): date time
Info CM-EVENT_FCIP_TUNNEL_UP, 4, FCIP tunnel n up
process_id (EvtMgr): date time
Error CM-EVENT_FCIP_WWN_MISMATCH, 2, FCIP tunnel WWN mismatch
process_id (EvtMgr): date time
Info CM-EVENT_FCR_EX_PORT_FABRIC_DONE, 4, FCR EX_Port fabric done at port n