HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)

34 Error messages
Recommended action
No action is required.
Severity
Info
CM-EVENT_FCIP_NTP_SYNC_STATE_DOWN
Message
Probable cause
The MP Router lost connectivity to the NTP server, and the switch clock has fallen out of synchronization.
The FCIP service stops enforcing WAN_TOV timeouts for ports configured for this feature.
Recommended action
Reconfigure the connection to a valid NTP server using the tsClockServer command.
Severity
Warning
CM-EVENT_FCIP_TUNNEL_DOWN
Message
Probable cause
FCIP tunnel n is down due to:
An administrator disabling the FCIP tunnel
A physical connectivity problem
A TCP connectivity timeout
Recommended action
1. Verify the physical link status using the portShow command on both ports in the connection.
2. Issue the rnPing command to the remote IP address to check for basic TCP connectivity.
3. Verify the configuration using the portCfgGige and portCfgFcip commands.
4. Verify that the SFP transceiver is seated correctly.
5. Check for faulty cables, deteriorated SFP transceivers, or dirty connections.
6. Replace the cables and SFP transceivers, if necessary.
Severity
Critical
process_id (EvtMgr): date time
Warning CM-EVENT_FCIP_NTP_SYNC_STATE_DOWN, 3, NTP clock lost synchronization,
disabling FCIP WAN_TOV enforcement.
process_id (EvtMgr): date time
Critical CM-EVENT_FCIP_TUNNEL_DOWN, 1, FCIP tunnel n down