HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)

30 Error messages
CM-EVENT_FAN_INSERT
Message
Probable cause
Fan n was inserted into the chassis.
Recommended action
No action is required.
Severity
Info
CM-EVENT_FAN_REMOVE
Message
Probable cause
Fan n was removed from the chassis.
Recommended action
1. Replace the missing fan FRU.
2. Check the fan status using the fanShow command.
3. Verify that the operating temperatures of the switch are acceptable using the tempShow command.
Fan problems often result in the chassis overheating, which can damage the switch.
Severity
Warning
CM-EVENT_FAN_UP
Message
Probable cause
Fan n is up.
Recommended action
No action is required.
Severity
Info
process_id (EvtMgr): date time
Info CM-EVENT_FAN_INSERT, 4, Fan n inserted
process_id (EvtMgr): date time
Warning CM-EVENT_FAN_REMOVE, 1, Fan n removed
process_id (EvtMgr): date time
Info CM-EVENT_FAN_UP, 4, Fan n up