HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)

XPath OS 7.4.x system error messages reference guide 29
Recommended action
No action is required.
Severity
Info
CM-EVENT_FABRIC_ELEMENT_REBOOT
Message
Probable cause
A user-initiated switch reboot or power cycle occurred. Possible values for Restart reason are:
Reboot
Unknown
Recommended action
No action is required.
Severity
Info
CM-EVENT_FAN_DOWN
Message
Probable cause
Fan n is down.
Recommended action
1. Verify that the operating temperatures of the switch are acceptable using the tempShow command.
Fan problems often result in the chassis overheating, which can damage the switch.
2. Check the fan status using the fanShow command.
3. Try reseating the specified fan FRU.
4. If the problem persists, replace the fan field-replaceable unit (FRU).
Severity
Warning
process_id (EvtMgr): date time
Info CM-EVENT_FABRIC_ELEMENT_REBOOT, 4, SYS-BOOT Restart reason: reason
process_id (EvtMgr): date time
Warning CM-EVENT_FAN_DOWN, 3, Fan n down