HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)
28 Error messages
CM-EVENT_DIAG_XBAR_TEST
Message
Probable cause
The celloPortTest command failed. The central ASIC, the port ASIC, or both might be faulty.
Recommended action
Rerun the test using one-to-one configuration (destination port equal source port) for all tested ports. If all
ports fail, either the central ASIC or all the ports are faulty. If some ports run successfully, the failing ports
are faulty. If all ports pass, the central ASIC is faulty. If the central ASIC is faulty, the switch must be
replaced.
Severity
Error
CM-EVENT_EPORT_SEGMENTATION_EVENT
Message
Probable cause
An E_Port segmentation occurred.
Recommended action
1. Verify that the SFP transceiver is seated correctly.
2. Check for faulty cables, deteriorated SFP transceivers, or dirty connections.
3. Replace the cables and SFP transceivers, if necessary.
Severity
Warning
CM-EVENT_EXTENDED_API_ZONE
Message
Probable cause
A zone database changed because of action. Valid values for action are zone committed
(cfgSave, cfgDisable, or cfgEnable) or zone merged.
process_id (EvtMgr): date time
Error CM-EVENT_DIAG_XBAR_TEST, 2, Diag celloporttest failed
process_id (EvtMgr): date time
Warning CM-EVENT_EPORT_SEGMENTATION_EVENT, 3, E-port segmentation occurred at
port n, incompatible
process_id (EvtMgr): date time
Info CM-EVENT_EXTENDED_API_ZONE, 4, Zone database action