CM-EVENT_DIAG_POST_COMPLETE
Message
Probable cause
The POST (power-on self-test) completed successfully.
Recommended action
No action is required.
Severity
Info
CM-EVENT_DIAG_SPIN_SILK
Message
Probable cause
The spinSilk command failed for one of the following reasons:
• The cable is not connected properly or the SFP transceiver is not seated correctly.
• The central ASIC is faulty.
• One or more port ASICs are faulty.
Recommended action
1. Verify that the MP Router is cabled correctly for the test.
Some diagnostic tests require special cabling configurations or loopback plugs. See the HP
StorageWorks XPath OS 7.4.x command reference guide for information on this test.
2. Verify that the SFP transceiver or loopback plug is seated correctly.
3. Check for faulty cables, deteriorated SFP transceivers, or dirty connections.
4. Replace the cables and SFP transceivers, if necessary.
5. Use the portShow command to determine which port is faulty, and do not use the port.
A faulty port ASIC does not affect any other port in the switch. The unit can be used until the port is
needed to add switch capacity.
6. Use the celloPortTest command to verify whether the central ASIC is faulty.
If the central ASIC is faulty, the switch needs to be replaced immediately.
Severity
Error
process_id (EvtMgr): date time
Info CM-EVENT_DIAG_POST_COMPLETE, 4, Diag POST complete
process_id (EvtMgr): date time
Error CM-EVENT_DIAG_SPIN_SILK, 2, Diag spinsilk test failed