HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)

26 Error messages
Recommended action
1. Verify that the MP Router is cabled correctly for the test.
Some diagnostic tests require special cabling configurations or loopback plugs.
2. Verify that the SFP transceiver or loopback plug is seated correctly.
3. If the port continues to fail, it usually means that the port ASIC is faulty, so do not use the port.
A faulty port ASIC does not affect any other port in the switch. The unit can be used until the port is
needed to add switch capacity.
4. Rerun the portLoopbackTest command using the other MAC setting (either FC or Gigabit Ethernet)
on the port.
This error might indicate that a particular MAC setting for the port is faulty, while the other MAC setting
works correctly. For more information on these commands and various test modes available, see the HP
StorageWorks XPath OS 7.4.x command reference guide.
Severity
Error
CM-EVENT_DIAG_PORT_MEM_ARM_TEST
Message
Probable cause
The diagPortMemarm test failed for a port.
Recommended action
Use the portShow command to determine which port is faulty. If the port ASIC is faulty, do not use the
port. A faulty port ASIC does not affect any other port in the switch. The unit can be used until the port is
needed to add switch capacity.
Severity
Error
CM-EVENT_DIAG_PORT_MEM_TEST
Message
Probable cause
The diagPortMem test failed for a port.
Recommended action
Use the portShow command to determine which port is faulty. If the port ASIC is faulty, do not use the
port. A faulty port ASIC does not affect any other port in the switch. The unit can be used until the port is
needed to add switch capacity.
Severity
Error
process_id (EvtMgr): date time
Error CM-EVENT_DIAG_PORT_MEM_ARM_TEST, 2, Diag diagportmemarm failed
process_id (EvtMgr): date time
Error CM-EVENT_DIAG_PORT_MEM_TEST, 2, Diag diagportmem failed