HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)
24 Error messages
2. Use the celloPortTest command to verify whether the central ASIC is faulty.
If the central ASIC is faulty, the switch needs to be replaced immediately.
Severity
Error
CM-EVENT_DIAG_ASIC_TEST
Message
Probable cause
The diagPortMailbox command failed for a port.
Recommended action
Use the portShow command to determine which port is faulty. If the port ASIC is faulty, do not use the
port. A faulty port ASIC does not affect any other port in the switch. The unit can be used until the port is
needed to add switch capacity.
Severity
Error
CM-EVENT_DIAG_CELLO_MEM
Message
Probable cause
The celloMemTest command failed and the central ASIC is corrupted or damaged.
Recommended action
If the central ASIC is faulty, the switch needs to be replaced immediately.
Severity
Critical
CM-EVENT_DIAG_CROSS_PORT_TEST
Message
Probable cause
The diagnostic cross-port test failed for one of the following reasons:
• Ports are not cabled correctly or the small-form-factor pluggable (SFP) transceiver is not seated correctly.
• The port ASIC is faulty.
process_id (EvtMgr): date time
Error CM-EVENT_DIAG_ASIC_TEST, 2, Diag diagportmailbox failed
process_id (EvtMgr): date time
Critical CM-EVENT_DIAG_CELLO_MEM, 1, Diag cellomemtest failed
process_id (EvtMgr): date time
Error CM-EVENT_DIAG_CROSS_PORT_TEST, 2, Diag crossporttest failed