CM-EVENT_CONSOLE_LOST_CARRIER_SIGNAL
Message
Probable cause
The console connection was lost, typically due to an unplugged or damaged cable. The serial connection
session is closed.
Recommended action
1. Verify that the serial console cable is connected.
2. Try to re-establish the connection.
3. If the connection still fails, either check to see if the cable is damaged or replace the cable.
Severity
Warning
CM-EVENT_DIAG_ASIC_REV
Message
Probable cause
An ASIC diagnostic test failed.
Recommended action
There are two types of application-specific integrated circuits (ASICs) in the MP Router: a per-port ASIC and
a central ASIC.
1. Use the diagPortMem command to determine whether a port ASIC is faulty.
If the port ASIC is faulty, do not use the port. A faulty port ASIC does not affect any other port in the
switch. The unit can be used until the port is needed to add switch capacity.
process_id (EvtMgr): date time
Warning CM-EVENT_CONSOLE_LOST_CARRIER_SIGNAL, 3, Console lost carrier signal
process_id (EvtMgr): date time
Error CM-EVENT_DIAG_ASIC_REV, 2, Diag asicrevshow failed