HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)

104 Error messages
ZONE-SHM_MALLOC
Message
Probable cause
A problem occurred while initializing the ZSD zone daemon and shared memory allocation. This message
usually indicates an XPath OS firmware problem.
Recommended action
1. Reboot or power cycle the MP Router.
2. If the problem persists, run the firmwareDownload command to upgrade the firmware.
Severity
Critical
ZONE-SWAL_INIT
Message
Probable cause
A problem occurred while initializing the SWAL daemon and establishing the CSCN connection for zone
commands. This message usually indicates an XPath OS firmware problem.
Recommended action
1. Reboot or power cycle the MP Router.
2. If the problem persists, run the firmwareDownload command to upgrade the firmware.
Severity
Critical
ZONE-XBAR_INIT
Message
Probable cause
A problem occurred initializing the ZSD zone daemon and establishing an xbar connection. This message
usually indicates an XPath OS firmware problem.
Recommended action
Reboot or power cycle the MP Router.
Severity
Critical
process_id (zsd): date time
Critical ZONE-SHM_MALLOC, 1, Shared memory allocation failed
process_id (zsd): date time
Critical ZONE-SWAL_INIT, 1, SWAL Initialization fails function_name
process_id (zsd): date time
Critical ZONE-XBAR_INIT, 1, XBAR init fails