HP StorageWorks XPath OS 7.4.X System Error Messages Reference Guide (AA-RVHGC-TE, September 2005)
102 Error messages
SWAL-SB_INIT_FAILURE
Message
Probable cause
An error was encountered when initializing the CSCN connection to the SB. This is a rare message, and
might indicate a problem with the XPath OS firmware. The functions that might be affected are:
• SwFmXferInforPvt
• SwFmXferInforPvtData
Recommended action
Use the firmwareDownload command to update the firmware and reboot the MP Router. For
instructions on how to download new firmware, see the HP StorageWorks XPath OS 7.4.x administrator
guide.
Severity
Critical
Zone module messages
This section describes the Zone module (ZONE) system error messages.
ZONE-CSCN_ALLOC_FAIL
Message
Probable cause
A CSCN buffer allocation failed. The system might have a CSCN buffer leak. The functions that might be
affected are:
• sb_alloc
• zs_send_brcdcmd_tons
• zs_send_cscn
• zs_send_cscnmsg
• zs_send_disable_tons
• zs_send_enable_tons
Recommended action
1. Reboot or power cycle the MP Router.
2. If the problem persists, run the firmwareDownload command to upgrade the firmware.
Severity
Critical
process_id (module_name): date time
Critical SWAL-SB_INIT_FAILURE, 1, Connection to SB failed: function_name
file_name line_number
process_id (zsd): date time
Critical ZONE-CSCN_ALLOC_FAIL, 1, CSCN buffer alloc failed function_name