HP StorageWorks XPath OS 7.4.X Administrator Guide (AA-RVHDD-TE, February 2006)
60 Using the FC-FC Routing Service
See the HP StorageWorks XPath OS 7.4.x command reference guide for details about the
portCfgExPort command and other XPath OS commands.
Once the port is properly configured and connected, log in to the MP Router and issue the switchShow
command. For example:
The McDATA switch connected to the MP Router’s EX_Port is visible. On the McDATA side, the show
command also shows the front domain.
If the LSAN is configured and the proxy devices are created, the proxy device shows up in the Name
Server of the edge fabric. The xlate domain also shows in the fabric of the edge fabric.
Table 6 portCfgExPort -m interop parameters
Value Description
0HP Native (default)
1McDATA Open mode
router:admin> switchshow
Switch Name : routerA
Switch State : Online
Switch Type : 38.2
Switch Role : Subordinate
Switch Domain: 1
Switch ID : FFFC01
Switch WWN : 10:00:00:05:1e:15:02:00
beacon status: OFF
zoning : OFF
FC router BB Fabric ID: 1
Port Media Speed State Info
=======================================
0 id N1 Online EX_PORT 10:00:08:00:88:40:50:ac "" (fabric id = 10)
1 id N1 Online EX_PORT 10:00:08:00:88:40:50:ac "" (fabric id = 10)
2 id N2 Online E_PORT 10:00:00:05:1e:13:83:00 "routerB" (upstream)
(output truncated)
13 -- AN No_Module
14 id N2 Online EX_PORT 10:00:00:60:69:80:04:98 "sw12kA21" (fabric id = 11)
15 id N2 Online EX_PORT 10:00:00:60:69:80:04:98 "sw12kA21" (fabric id = 11)
router:admin>