HP StorageWorks XPath OS 7.4.X Administrator Guide (AA-RVHDD-TE, February 2006)
XPath OS 7.4.x administrator guide 27
5. Issue the portstart command to start the ports. For example:
portstart 8-15
6. Issue the portenable command to enable the ports. For example:
portenable 8-15
7. Option: Issue the portshow command to verify that the newly active ports are Started.
NOTE: If you remove the HP StorageWorks MP Router Upgrade License, ports 8 through 15 no longer
work after the next reboot.
Setting the domain ID
A domain ID is assigned dynamically when a switch is enabled. However, the domain ID can be set
manually, for example, if you need to control the number to resolve a domain ID conflict when merging
fabrics.
Displaying a list of current domain IDs in the fabric
1. Log in as admin.
2. Issue the fabricShow command:
Fabric information is displayed, including the domain ID (listed in the Switch ID column).
To prevent a domain ID conflict, make sure all domain IDs are unique before connecting an MP Router to
the fabric.
Assigning a domain ID manually
1. Log in as admin.
2. Issue the switchDisable command to disable the switch.
3. Issue the configure command.
4. Enter a unique domain ID at the domain ID prompt.
5. Press Enter in response to the remaining prompts.
6. Issue the switchEnable command to re-enable the switch.
router:admin> fabricshow
Switch ID Worldwide Name Enet IP Addr Name
---------------------------------------------------------
74: fffc4a 10:00:00:60:69:50:09:1a 192.168.172.74 "mw74"
75: fffc4b 10:00:00:60:69:50:08:35 192.168.172.75 “mw75”
100: fffc64 10:00:00:05:1e:13:8b:00 192.168.163.103 "apswitch"
103: fffc67 10:00:00:05:1e:13:83:00 192.168.163.102 "ap_102"
The Fabric has 4 switches