HP StorageWorks Fabric OS 6.3.3d Release Notes (5697-0493, May 2010 - includes all 6.3.0x versions)
Fixed in Fabric OS 6.3.0c
Workaround prior to upgrade: Issue
cryptocfg --commit again to
sync up the VT/VI database across
nodes in the EG.
The host failed to discover tapes due to a VI/VT (Virtual Initiator/Virtual
Target) database mismatch between the switches that are part of the
same Encryption Group (EG). Therefore, the host cannot discover tape
devices that are part of the same EG.
Fixed in Fabric OS 6.3.0c
Common Access Library Daemon (CALD) detects a large memory in-
crease on the HP StorageWorks 2408 FCoE switch when running mul-
tiple SMIA clients over FCoE.
Fixed in Fabric OS 6.3.0c
The loginshow command on an FCoE switch displays unexpected
values when an LP21000 or LP21002 CNA is moved between switches.
Fixed in Fabric OS 6.3.0c
Workaround prior to upgrade: Issue
cryptocfg --show -groupcfg
and cryptocfg --show
-localEE commands to show the
health of the EG (Encryption Group).
In a remote corner case, an IPC failure message appears on one of the
nodes when using the cryptocfg --show -groupmember -all
command.
Fixed in Fabric OS 6.3.0c
Running Fabric OS commands on the default switch with virtual fabrics
enabled, after performing multiple cfgenable commands with TI zones
enabled, causes a No space left on device error, and no further
Fabric OS commands can be executed.
Fixed in Fabric OS 6.3.0c
In a multi-circuit FCIP tunnel configuration with 1606 Extension SAN
switch, or multiprotocol extension blade, circuit failover on 1 Gb tunnels
may not fail over to other available circuits with two rate limited circuits.
Fixed in Fabric OS 6.3.0c
Workaround prior to upgrade:
Disable FICON XRC Emulation.
Due to slow read track performance when XRC emulation is enabled,
MVS I/O errors are generated when an invalid selective reset frame is
sent to the controller, causing Abort Sequences later on.
Fixed in Fabric OS 6.3.0c
Need additional information of EE (Encryption Engine) status for the
entire EG (Encryption Group) in a single command. Currently we have
to invoke cryptocfg --show -groupcfg", cryptocfg --show
-groupmember -all, or cryptocfg --show -localEE on all
nodes to know the overall state of EG including EE state across the EG.
.
Fixed in Fabric OS 6.3.0c
Workaround prior to upgrade:
Disable auditing via auditcfg
-disable.
When auditing is on for security class, a race condition can occur in
raslogd, which leads to a switch panic or hafailover.
Fixed in Fabric OS 6.3.0c
Workaround prior to upgrade:
Disable FICON XRC emulation.
IFCCs are encountered when processing Read Channel Extender Cap-
abilities with XRC Emulation (IPLing systems with SDM LPARs).
Fixed in Fabric OS 6.3.0c
RNID frame type field from the host is corrupted internally when the
host is connected over FCIP, and is rejected by the switch. This results
in the switch being unable to get FICON CHPID online to VSM (Virtual
Tape Subsystem) over an emulated or non-emulated VE tunnel. The
E_Port between switches functions correctly.
HP StorageWorks Fabric OS 6.3.0d Release Notes 77