HP StorageWorks Fabric OS 6.3.1c Release Notes (5697-0509 September 2010 - includes all 6.3.1x versions)

CommentsDCFMWebTools 6.1.0Function
Configure > FCIP tunnel
Port Admin Module >
GigE tab
GigE ports interface
Configure > FCIP tunnel
Port Admin Module >
GigE tab
GigE ports route
In WebTools,
non-local switch
port id/WWN
can be added us-
ing text box.
Configure > Zoning
Zone Admin
Admin Domain
Switch Admin > DCC
policies
Performance Monitoring
Non-local switch ports
display in zoning tree
Configure > Zoning
Replace/Replace All zone
members by selecting the offline
devices from the zone tree.
Offline devices have an unknown
overlay badge with good
visibility.
Zone Admin
Remove Offline or inac-
cessible Devices
Configure > Zoning
Zoning report for both online and
offline database
Zone Admin
Zone database summary
ping
Encryption behavior
HP recommends that the encrypted LUN containers be created when all of the nodes/encryption
engines (EEs) in the Data Encryption Key (DEK)/High Availability Cluster (HAC) are up and enabled.
If two Encryption Engines are part of a High Availability Cluster, configure the host/target pair
such that they form a multipath from both EEs. Avoid connecting both the host/target pairs to
the same EE. This connectivity does not give full redundancy in case of EE failure resulting in
HAC failover.
Since the quorum disk plays a vital role in keeping the cluster in sync, configure the quorum
disk to be outside of the encryption environment.
LUN configuration
To configure a LUN for encryption:
Add the LUN as clear-text to the Crypto Target Container (CTC).
When the LUN comes online and the clear-text host I/O starts, modify the LUN from clear-
text to encrypted, including the enable_encexistingdata option to convert the LUN
from clear-text to encrypted.
An exception to this LUN configuration process: If the LUN was previously encrypted by the
HP Encryption Switch or HP Encryption Blade, the LUN can be added to the CTC with the
–encrypt and –lunstate =“encrypted” options.
LUN configurations must be committed to take effect. No more than 25 LUNs can be added
or modified in a single commit operation. Attempts to commit configurations that exceed 25
LUNs will fail with a warning. There is also a five-second delay before the commit operation
takes effect.
HP StorageWorks Fabric OS 6.3.1c Release Notes 41