HP StorageWorks Fabric OS 5.2.x administrator guide (5697-0014, November 2009)
Fabric OS 5.2.x administrator guide 237
6. Log in to the switch and issue the nsAllShow or the nsCamShow command.
All of the devices from both LSANs should appear in the output. If the devices do not appear in the
output, issue the cfgShow command to verify your zone configuration. Use the cfgactvshow
command to display the zone configuration currently in effect. The following example illustrates the use
of cfgactvshow.
7. Log into the FC router and run the lsanZoneShow command to verify FIDs and devices to be shared
among LSANs.
edgeswitch:admin_06> nsallshow
{
010e00 020000 03f001 04f002
4 Nx_Ports in the Fabric }
edgeswitch:admin_06> nscamshow
nscam show for remote switches:
Switch entry for 1
state rev owner
known v520 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 010e00; 3;10:00:00:00:00:01:00:00;10:00:00:00:00:00:01:00;
Fabric Port Name: 20:0e:00:60:69:e2:18:b6
Permanent Port Name: 10:00:00:00:00:01:00:00
Port Index: 14
Share Area: No
Device Shared in Other AD: No
Switch entry for 3
state rev owner
known v410 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 03f001; 2,3;10:00:00:00:c9:44:54:04;20:00:00:00:c9:44:54:04;
FC4s: FCP
NodeSymb: [36] "Emulex LP9002 FV3.92A2 DV5-5.10A10 "
Fabric Port Name: 50:00:51:e3:70:9a:3d:e8
Permanent Port Name: 10:00:00:00:c9:44:54:04
Port Index: na
Share Area: No
Device Shared in Other AD: No
Switch entry for 4
state rev owner
known v410 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 04f002; 3;10:00:00:00:00:03:00:00;10:00:00:00:00:00:03:00;
Fabric Port Name: 50:06:06:91:23:45:6a:13
Permanent Port Name: 10:00:00:00:00:03:00:00
Port Index: na
Share Area: No
Device Shared in Other AD: No
switch:admin> cfgactvshow
Effective configuration:
cfg: test
zone: lsan_san
10:00:00:00:00:03:00:00
10:00:00:00:00:01:00:00
zone: lsan_test
50:06:01:60:38:e0:0b:a4
10:00:00:00:c9:44:54:04