HP StorageWorks Fabric OS 5.2.x administrator guide (5697-0014, November 2009)

Fabric OS 5.2.x administrator guide 231
McDATA connection mode to McDATA fabric.
8. Enable the port by issuing the portEnable command.
Connect IFL 1 and verify EX_PORT connectivity. Repeat for all HP fabric IFLs.
Connect IFL (n) for the McDATA fabric and verify EX_PORT connectivity. Repeat for all McDATA
fabric IFLs.
9. Log in to the FC router and issue the switchShow command to display the McDATA switch that is
connected to the FC router EX_Port. The following example illustrates the use of the
SWITCHSHOW
command.
The output from the switchshow command is show in the following example:
10. You can now physically attach your ISLs from the 400 MP Router and B-Series MP Router (FR4-18i)
blade to the switches.
ISLs apply only to HP switches that are not connected as an edge fabric (IFLs). When a McDATA switch
is present, it is assumed that you are creating an edge fabric.
switch:admin_06> portcfgexport 10/13 -a 1 -f 37 -m 2
switch>:admin_06 portenable 10/13
switch>:admin_06 > switchshow
switchName: b48000_5x_1
switchType: 42.2
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 3
switchId: fffc03
switchWwn: 10:00:00:60:69:e4:00:86
zoning: ON (test)
switchBeacon: OFF
blade3 Beacon: OFF
blade8 Beacon: OFF
blade10 Beacon: OFF
FC Router: ON
FC Router BB Fabric ID: 1
Index Slot Port Address Media Speed State Proto
===================================================
112 10 0 037000 id N4 No_Light Disabled (Persistent)
113 10 1 037100 id N4 No_Light Disabled (Persistent)
114 10 2 037200 id N4 No_Light Disabled (Persistent)
115 10 3 037300 id N4 No_Light Disabled (Persistent)
116 10 4 037400 id N4 No_Light Disabled (Persistent)
117 10 5 037500 id N4 No_Light Disabled (Persistent)
118 10 6 037600 id N4 No_Light Disabled (Persistent)
119 10 7 037700 id N4 No_Light Disabled (Persistent)
120 10 8 037800 id N4 No_Sync Disabled (Persistent)
121 10 9 037900 id N2 No_Light
122 10 10 037a00 id N2 No_Light
123 10 11 037b00 id N2 No_Light
124 10 12 037c00 id N2 Online EX-Port 10:00:00:05:1e:34:e0:6a "b4100_5x_1"
(fabric id = 41 )
125 10 13 037d00 id N2 Online EX-Port 10:00:08:00:88:03:53:fc "mcd_37"
(fabric id = 37 )
126 10 14 037e00 id N2 No_Light
127 10 15 037f00 id N2 No_Light
240 10 16 03f000 -- -- Offline Disabled (Persistent)
241 10 17 03f100 -- -- Offline Disabled (Persistent)
242 10 18 03f200 -- -- Offline Disabled (Persistent)
243 10 19 03f300 -- -- Offline Disabled (Persistent)
...this example has been truncated