Brocade Fabric Watch Administrator's Guide - Supporting Fabric OS v5.3.0 (53-1000438-01, June 2007)
74 Fabric Watch Administrator’s Guide
53-0000438-01
Port class
Table 26 provides default settings for areas in the F/FL_Port class.
TABLE 26 F/FL_Port class threshold defaults
Area Description Default threshold settings Default alarm settings Threshold state
Loss of
Synchronization
Count
Monitors the
number of loss of
synchronization
errors
Unit: Error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Receive Performance Monitors the
receive rate, by
percentage
Unit: Percentage(%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Informative
State Changes Monitors state
changes
Unit: Change(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Transmit
Performance
Monitors the
transmit rate, by
percentage
Unit: Percentage(%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Informative
Invalid CRC Count Monitors the
number of CRC
errors
Unit: Error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Invalid Transmission
Word
Monitors the
number of invalid
words transmitted
Unit: Error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Link Failure Count Monitors the
number of link
failures
Unit: Error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Loss of Signal Count Monitors the
number of signal
loss errors
Unit: Error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Primitive Sequence
Protocol Error
Monitors the
number of primitive
sequence errors
Unit: Error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range