Brocade Fabric Watch Administrator's Guide - Supporting Fabric OS v5.3.0 (53-1000438-01, June 2007)

Fabric Watch Administrator’s Guide 61
53-0000438-01
Types of Fabric Watch reports
4
208 G HEALTHY 000:00 - - - - - - - - - - - - -
209 G HEALTHY 000:00 - - - - - - - - - - - - -
210 G HEALTHY 000:00 - - - - - - - - - - - - -
211 G HEALTHY 000:00 - - - - - - - - - - - - -
212 G HEALTHY 000:00 - - - - - - - - - - - - -
213 G HEALTHY 000:00 - - - - - - - - - - - - -
214 G HEALTHY 000:00 - - - - - - - - - - - - -
215 G HEALTHY 000:00 - - - - - - - - - - - - -
216 VE HEALTHY 061:19 - - - - - - - - - - - - -
217 VE HEALTHY 061:19 - - - - - - - - - - - - -
218 VE HEALTHY 061:19 - - - - - - - - - - - - -
219 VE HEALTHY 003:37 - - - - - - - - - - - - -
220 VE HEALTHY 002:48 - - - - - - - - - - - - -
221 VE HEALTHY 061:19 - - - - - - - - - - - - -
222 VE HEALTHY 061:19 - - - - - - - - - - - - -
223 VE HEALTHY 061:19 - - - - - - - - - - - - -
NOTE
Output of the Port Detail Report depends on the ports that belong to the current Admin Domain
context. If a port does not belong to the current Admin Domain, nothing other than port number is
displayed for that port.
Example:
“000 ----------------Not a member of current Admin Domain-------------------”
Table 17 lists and describes each item in the port detail report.
TABLE 17 Port detail report columns
Report item Description
LFA Link Loss: the number of link loss occurrences out of range for time period
LSY Sync Loss: the number of sync loss occurrences out of range for time period
LSI Signal Loss: the number of signal loss occurrences out of range for time period
PER Protocol Error: the number of protocol errors out of range for time period
INW Invalid word. The number of invalid words out of range for time period
CRC Invalid CRC: the number of CRC errors out of range for time period
PSC Port hardware state changed too often due to fabric reconfiguration
BLP Buffer limited port: the switch status changes when a port is in a buffer limited mode based
on the switch status policy.
STM SFP temperature is out of specifications
SRX SFP receive power is out of specifications
STX SFP transmit power is out of specifications
SCU SFP current is out of specifications
SVO SFP voltage is out of specifications