Brocade Fabric OS MIB Reference - Supporting Fabric OS 5.3.0 (53-1000439-01, June 2007)

58 Fabric OS MIB Reference
53-1000439-01
fcFeModuleLastChange 1.3.6.1.2.1.75.1.1.4.1.5
3
fcFeModuleLastChange 1.3.6.1.2.1.75.1.1.4.1.5
Contains the value of sysUpTime when the module entered its current operational status. A value
of 0 indicates that the operational status of the module has not changed since the agent last
restarted.
fcFeModuleFxPortCapacity 1.3.6.1.2.1.75.1.1.4.1.6
The number of Fx_Ports that can be contained within the module. Within each module, the ports
are uniquely numbered in the range from 1 to fcFeModuleFxPortCapacity, inclusive. However, the
numbers are not required to be contiguous.
Values Valid values are:
Brocade 3200, 3250 8 ports
Brocade 4012 12 ports
Brocade 200E, 3800, 3850 16 ports
Brocade 3900, 4100 32 ports
Brocade 4900, 50 ports
Brocade 5000 32 ports
Brocade 7500 16 ports
Brocade 7600 16 ports
Brocade 12000 / 24000 128 ports
Brocade 48000 256 ports
fcFeModuleName 1.3.6.1.2.1.75.1.1.4.1.7
The Name_Identifier of the module.
Return Displays the WWN of the switch.
fcFxPortTable 1.3.6.1.2.1.75.1.1.5
A table that contains configuration and service parameters of the Fx_Ports, one entry for each
Fx_Port in the fabric element.
fcFxPortEntry 1.3.6.1.2.1.75.1.1.5.1
An entry containing the configuration and service parameters of an Fx_Port.
Index 1: fcFeModuleIndex
2: fcFxPortIndex