Brocade Fabric OS MIB Reference - Supporting Fabric OS 5.3.0 (53-1000439-01, June 2007)

Fabric OS MIB Reference 247
53-1000439-01
connUnitSensorStatusChange
8
connUnitEventDescr.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = FW-1425
Switch status changed from MARGINAL to HEALTHY.
See the swEventTrap for more details.
connUnitSensorStatusChange
Enterprise fcmgmt
Variables connUnitSensorStatus
Overall status of the connectivity unit has changed.
This trap is generated whenever the status of the sensors (like fan, power supply, temperature)
present in the connectivity unit changes.
Sample trap output for Fabric OS v4.4.0:
connUnitSensorStatus.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.7 = failed(5)
See the Fabric Watch Administrator’s Guide for information on configuring thresholds that generate
these traps.