Brocade Fabric OS MIB Reference - Supporting Fabric OS 5.3.0 (53-1000439-01, June 2007)
132 Fabric OS MIB Reference
53-1000439-01
swSensorScn 1.3.6.1.4.1.1588.2.1.1.1.0.2
5
swSensorScn 1.3.6.1.4.1.1588.2.1.1.1.0.2
(Obsoleted by swFabricWatchTrap)
Enterprise sw
Variables “swSensorStatus 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3”
“swSensorIndex 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1”
“swSensorType 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2”
“swSensorValue 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4”
“swSensorInfo 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5”
“swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10”
A swSensorScn (2) is generated whenever an environment sensor changes its operational state: for
instance, if a fan stop working. The VarBind in the Trap Data Unit contain the corresponding
instance of the sensor status, sensor index, sensor type, sensor value (reading), and sensor
information. Note that the sensor information contains the type of sensor and its number, in textual
format.
swFCPortScn 1.3.6.1.4.1.1588.2.1.1.1.0.3
Enterprise sw
Variables “swFCPortOpStatus 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4”
“swFCPortIndex 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1”
“swFCPortName 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.36”
“swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10”
A swFCPortScn (3) is generated whenever an FC_Port changes its operational state: for instance,
the FC_Port goes from online to offline. The VarBind in the Trap Data Unit contain the
corresponding instance of the FC_Port's operational status, index, swFCPortName, and swSsn.
swFCPortName and swSsn are optional.
#TYPE A sensor (temperature, fan, or other) changed its
operational state.
#SUMMARY %s: is currently in state %d and SSN is #%s
#ARGUMENTS 4, 0, 5
#SEVERITY Informational
#TIMEINDEX 1
#STATE Operational
#TYPE A Fibre Channel Port changed its operational state.
#SUMMARY Port Index %d changed state to %d. Port Name: %s and
SSN is #%s
#ARGUMENTS 1, 0, 2, 3