Brocade Fabric OS MIB Reference Guide v6.0.0 (53-1000602-01, April 2008)

Fabric OS MIB Reference 247
53-1000602-01
connUnitDeletedTrap
8
connUnitStatus.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.1 = warning(4)
connUnitState.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.1 = offline(3)
See the Fabric Watch Administrator’s Guide on how the switch status is determined.
connUnitDeletedTrap
Enterprise fcmgmt
Variables connUnitId
A connUnit has been deleted from this agent.
Recommended severity level (for filtering): warning.
Not implemented.
connUnitEventTrap
Enterprise fcmgmt
Variables connUnitEventId, connUnitEventType, connUnitEventObject, connUnitEventDescr
An event has been generated by the connectivity unit.
Recommended severity level (for filtering): info.
Sample trap output for Fabric OS v6.0.0:
connUnitEventId.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = 354
connUnitEventType.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = other(2)
connUnitEventObject.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = null
connUnitEventDescr.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.354 = FW-1425
Switch status changed from MARGINAL to HEALTHY.
See the swEventTrap for more details.
connUnitSensorStatusChange
Enterprise fcmgmt
Variables connUnitSensorStatus
Overall status of the connectivity unit has changed.
This trap is generated whenever the status of the sensors (like fan, power supply, temperature)
present in the connectivity unit changes.
Sample trap output for Fabric OS v6.0.0:
connUnitSensorStatus.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.7 = failed(5)
See the Fabric Watch Administrator’s Guide for information on configuring thresholds that generate
these traps.