HP StorageWorks 2300 Family Modular Smart Array CLI reference guide (500912-002, July 2010)

HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide 153
show ports
Description Shows information about host ports on both controllers.
Syntax
show ports
Output Port
Controller ID and port number
Media
FC(P): Fibre Channel Point-to-Point
FC(L): Fibre Channel-Arbitrated Loop
FC(-): Not applicable, as when the port is disconnected
SAS: Serial Attached SCSI
iSCSI: Internet SCSI
Target ID
Enclosure WWN or serial number
Status
Whether the port is operational, has a problem, or is disconnected
Speed (A)
Actual host-port link speed, or blank if not applicable.
Speed (C)
FC and SAS only. Configured host-port link speed:
FC: 2Gb or 4Gb (Gbit/sec)
SAS: 1Gb (Gbit/sec)
Blank if not applicable
Topo (C)
FC and SAS only. Configured topology
Width
SAS only. Number of SAS lanes in this port.
PID
FC and SAS only. Primary ID, or blank if not applicable
IP-Ver
iSCSI only. IPv4
PIP
iSCSI only. Primary IP address
SIP
iSCSI only. Secondary IP address. This field is only displayed during failover.
MAC
iSCSI only. Unique Media Access Control (MAC) hardware address, also called the physical
address.
Example Show port information for a system with two FC ports:
# show ports
Port Media Target ID Status Speed(A) Speed(C) Topo(C) PID
--------------------------------------------------------------------------
A1 FC(L) 207000C0FF000015 OK 2Gb 2Gb Loop 0
A2 FC(L) 217000C0FF000015 OK 2Gb 2Gb Loop 1
--------------------------------------------------------------------------