Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008)

98 HP StorageWorks 2000 Family Modular Smart Array CLI reference guide May 2008
rescan
Description
This command forces rediscovery of attached disk drives and enclosures. If both
Storage Controllers are online, it also forces re-evaluation of the enclosure IDs of
attached drive enclosures, so that IDs are assigned based on controller As enclosure
cabling order. A manual rescan may be needed after system power-up to display
enclosures in the proper order.
A manual rescan is not required to detect when drives are inserted or removed; the
controllers do this automatically. When drives are inserted they are detected after a
short delay, which allows the drives to spin up.
When you perform a manual rescan, it temporarily pauses all I/O processes, then
resumes normal operation.
Input
Example
Scan for device changes and re-evaluate enclosure IDs.
rescan
# rescan
Success: Command completed successfully