Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008)

198 HP StorageWorks 2000 Family Modular Smart Array CLI reference guide May 2008
show job-parameters
Description
Shows parameters for background scrub, partner firmware upgrade, and other jobs.
Input
Output
Example
Show a system's job parameters.
Related Commands
“set job-parameters” on page 137
show job-parameters
Field Description
Background Scrub Shows whether disks are automatically checked
for disk drive defects to ensure system health.
Partner Firmware Upgrade Shows whether component firmware versions
are monitored and will be automatically
upgraded on the partner controller.
Utility Priority Priority at which jobs (such as vdisk
verification and reconstruction but not
background scrub) run with respect to I/O
operations competing for the system's
processors: High, Medium, or Low.
# show job parameters
Job Parameters
--------------
Background Scrub : Enabled
Partner Firmware Upgrade: Enabled
Utility Priority : High