Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008)

186 HP StorageWorks 2000 Family Modular Smart Array CLI reference guide May 2008
show frus
Description
Shows information for all field-replaceable units (FRUs) in the controller enclosure
and in any attached drive enclosures. Some information reported is for use by
service technicians.
Input
Output
show frus
Field Description
Name FRU name:
CHASSIS_MIDPLANE: 2U chassis and midplane; the
metal enclosure and the circuit board to which power and
cooling, controller, expansion, and drive modules connect
RAID_IOM: Controller module
BOD_IOM: Expansion module
POWER_SUPPLY: Power and cooling module
Description FRU description
Part Number FRU part number
Mid-Plane SN For the CHASSIS_MIDPLANE FRU, the mid-plane serial
number
Serial Number For the RAID_IOM, BOD_IOM, and POWER_SUPPLY
FRUs, the FRU serial number
Revision FRU revision number
Dash Level FRU template revision number
FRU Shortname FRU part number
Mfg Date Date and time that the FRU was programmed
Mfg Location Location where the FRU was programmed
Mfg Vendor ID JEDEC ID of the manufacturer