Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008)
154 HP StorageWorks 2000 Family Modular Smart Array CLI reference guide • May 2008
set vdisk-spare
Description
Designates spare disk drives that can be used by a specific virtual disk, and sets the
disk drive status to
VDISK SP. A vdisk spare can be assigned to RAID 1, 3, 5, 6,
10, and 50 virtual disks, and must have enough capacity to replace the smallest disk
drive in the virtual disk.
Input
Example
Designate the disk drive having ID 5 in the controller enclosure as a vdisk spare for
virtual disk VD1.
Related Commands
■ “show disks” on page 174
■ “show vdisks” on page 230
set vdisk-spare disks disks vdisk
Parameter Description
disks disks Specifies up to four disk drives. For the syntax to use, see “Disk
Drive Syntax” on page 25.
vdisk Specifies the virtual disk by name or serial number. For the syntax
to use, see “Virtual Disk Syntax” on page 26.
# set vdisk-spare disks 0.5 VD1
Info: Disk 0.5 added to VD1.
Success: Command completed successfully