Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008)
182 HP StorageWorks 2000 Family Modular Smart Array CLI reference guide • May 2008
Output
Shows the following information for each event:
to date Optional. Shows events before and including the
specified date and time. Use the format
MMDDYYhhmmss, where hh is the hour on a 24-hour
clock. For example, 043006235900 represents Apr 30
2006 at 11:59:00 p.m. This parameter can be used with
either “from” parameter.
from-event ID Optional. Shows events including and after the specified
event ID. If this number is smaller than the ID of the
oldest event, events are shown from the oldest available
event. This parameter can be used with either “to”
parameter.
to-event ID Optional. Shows events before and including the
specified event ID. If this number is larger than the ID
of the oldest event, events are shown up to the latest
event. This parameter can be used with either “from”
parameter.
a|b|error Optional. Specifies to filter the event listing:
• a: Shows events from controller A only
• b: Shows events from controller B only
• error: Shows all warning and critical events but not
informational events
Field Description
Timestamp Day, date, time, and year when the event was logged
Event code Identifies the type of event and might help service technicians
diagnose problems; for example, [181]
Event ID Event number prefixed by A or B to indicate which controller module
logged the event; for example, #A123
Controller ID Model, serial number, and ID of the controller module that logged the
event
Parameter Description