Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008)
Chapter 3 Command Descriptions 159
show channels
Description
Shows information about host and expansion ports on both controllers.
Input
Output
show channels
Field Description
Ctlr Controller ID
Ch Port number
Type • Host: Host port
• Drive: Expansion port
Media • FC(P): Fibre Channel Point-to-Point
• FC(L): Fibre Channel-Arbitrated Loop
• FC(-): Not applicable
• SAS: Serial Attached SCSI
• iSCSI: Internet SCSI
Topo (C) FC or SAS only. Configured topology
Speed (A) Actual host-port link speed. Blank if not applicable
Speed (C) FC or SAS only. Configured host-port link speed:
•FC: 2G or 4G (Gbit/sec)
•SAS: 3G (Gbit/sec)
• Blank if not applicable
Status Whether the port is operational (Up) or not (Down)
PID FC or SAS only. Primary ID, or blank if not applicable
SID FC or SAS only. Secondary ID, or blank if not applicable