Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008)
128 HP StorageWorks 2000 Family Modular Smart Array CLI reference guide • May 2008
Example
Disable the first egress PHY in both controllers in an enclosure, after determining
the PHY index; then verify the PHY’s status.
Related Commands
■ “set expander-fault-isolation” on page 125
■ “show enclosure-status” on page 178
■ “show expander-status” on page 184
# show expander-status
Encl Phy Type Status
-------------------------------------
0 0 DRIVE OK <= Index 0
0 1 DRIVE OK
0 2 DRIVE OK
0 3 DRIVE OK
0 4 DRIVE OK
0 5 DRIVE OK
0 6 DRIVE OK
0 7 DRIVE OK
0 8 DRIVE OK
0 9 DRIVE OK
0 10 DRIVE OK
0 11 DRIVE OK
0 0 INTER-EXP OK <= Index 12
0 1 INTER-EXP OK
0 2 INTER-EXP OK
0 3 INTER-EXP OK
0 0 SC OK
0 1 SC OK
0 2 SC OK
0 3 SC OK
0 0 EGRESS Error <= Index 20
...
# set expander-phy wwn 500C0FF00A408A3C controller both index 20
disable
Success: Disabled Phy #20.
# show expander-status
...
0 0 EGRESS Disabled
...