Hp StorageWorks 2000 Family Modular Smart Array CLI reference guide (481600-002, May 2008)

Chapter 3 Command Descriptions 119
Example
Set CLI to use a 30-second timeout, base 2, and no paging.
Related Commands
“show cli-parameters” on page 164
disk-addressing
enclosure-slot|
channel-id
Optional. Sets the format in which drive IDs are
shown and must be specified.
enclosure-slot: Drives are shown, and must
be specified, with the format enclosure-
ID.drive-slot-number. This is the default.
For example, the first drive in the second enclosure
(enclosure ID 1) has address 1.0.
channel-id: Drives are shown, and must be
specified, by SCSI ID. For example, the first drive
in the second enclosure has address 16.
# set cli-parameters timeout 30 base 2 pager disabled
Success: CLI parameter changed successfully