HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)
Message Type
Description Action
319 FAN FLASH DONE
ON BOX #<n>
Informational
Indicates that the array controller
has completed updating the
firmware on a fan module.
320 FAN FLASH
FAILED ON BOX #<n>
Error
Indicates tha
t the array controller
was unable to u
pdate the firmware
on a fan module
.
Retry the operation. Contact HP
support if the problem persists.
321 BATTERIES LOW,
FLASH REFUSED
Error
The array controller was unable to
proceed with a firmware flashing
or cloning operation because
the cache batteries are low and
there is a risk of data loss if the
operation fails.
Allow the controller to charge its
batteries, and then retry the flash
operation.
330 AUTO-UPGRADE
IN PROGRESS
Informational
The array controller has detected
that firmware upgrades are needed
to other MSA components and is
preparing to perform the upgrade.
331 AUTO-UPGRADE
DONE
Informational
The array controller has completed
upgrading MSA components.
332 AUTO-UPGRADE
FAILED
Error
The array controller was unable to
upgrade all MSA components.
Check previous error messages
to determine which components
failed to upgrade, and verify that
these components are working
properly. The upgrade can be
retried the next time the MSA is
rebooted.
333 AUTO-UPGRADE
REQUIRES REBOOT
Informational
The array controller completed
upgrading MSA components and
requires the MSA to be rebooted
before the upgrades can take
effect.
Reboot the MSA to complete the
upgrade process.
400 STORAGE BOX
#<n> FAN OK
Informational
Afan
in the specified storage
enc
losure that was previously
mar
kedasfailedordegradedis
now
operating normally.
401 STORAGE BOX
#<n> FAN FAILED
Error
A fan in the specified storage
enclosure has failed. The MSA
may now be susceptible to
overheating if corrective action is
not taken.
Check all fans to ensure they are
operating. Replace any failed
fans.
402 STORAGE BOX
#<n> FAN DEGRADED
Informational
Anfaninthespecified storage
enclosure has been hot added.
Check all fans to ensure they are
operating. Replace any failed
fans.
403 STORAGE BOX
#<n> FAN HOT
INSERTED
Informational
Anfaninthespecified storage
enclosure has been hot added.
404 STORAGE BOX
#<n> FAN HOT
REMOVED
Informational
A fan in the specified storage
enclosure has been removed.
405 STORAGE BOX
#<n> TEMPERATURE
OK
Informational
The temperature in the specified
storage enclosure is now back in
the normal operating range.
124
MSA controller LCD panel message descriptions