HP StorageWorks 1510i Modular Smart Array installation and user guide (383070-002, July 2008)

Message Type
Description Action
73 CACHE HARDWARE
BATTERIES MISSING
Error
The cache module does not have
its required batteries attached to it.
If the failure occurred on the
standby array controller, remove
the standby array controller,
remove cache, attach cache
batteries, replace the cache
modules, wait 10 seconds, and
then reinsert the array controller,
ensuring that it is fully seated in
the chassis.
If the failure occurred on the
active array controller, wait until
downtime is available. Power
off the MSA, remove the array
controller, replace the cache
modules, and reinsert the array
controller, ensuring it is fully seated
in the chassis.
Should the issue persist, contact
HP support.
80 REPLACEMENT
DRIVE FOUND BOX
#<n> BAY <n>
Informational
ASCSIhar
d drive that was
previou
sly missing or failed has
now been
replaced with a working
SCSI dri
ve.
81 SMART DRIVE
ALERT BOX #<n>,
BAY <n>
Informational
ASCSIharddrivemaybecloseto
failing. This was determined either
by the hard drive rmware itself
using SMART technology or by the
arraycontrollerusingmonitorand
performance testing.
The hard drive should be replaced
as soon as possible.
82 DRIVE HOT ADDED
BOX #<n>, BAY <n>
Informational
ASCSIharddrivehasbeen
added to the system in the location
specied in the message.
83 DRIVE HOT
REMOVED BOX #<n>,
BAY <n>
Informational
ASCSIharddrivehasbeen
removed from the system in the
location specied in the message.
84 DRIVE FAILURE
BOX #<n>, BAY <n>
Error
A SCSI hard drive in the system
has failed. If the hard drive was
part of a congured volume, then
the state of the volume depends on
the fault tolerance used.
Replace the drive as soon as
possible.
85 BAD DRIVE
FIRMWARE BOX #<n>,
BAY <n>
Error
A SCSI drive has been detected
that has known, bad rmware
on it. Continued usage of this
drive could result in drive failure,
decreased performance or data
loss.
Update the hard drive rmware or
replace the hard drive as soon as
possible.
86 DRIVE POSITION
CHANGE DETECTED
Informational
The SCSI hard drives that make
up a congured volume have
been physically moved within
the system. The array controller
has updated its conguration
information accordingly.
87 DRIVE POSITION
CHANGE INVALID
Informational
The SCSI hard drives that make
up a congured volume have
been physically moved in such a
way that the array controller can
no longer access the congured
volume.
Power the MSA off and restore
drives to their original positions.
1510i Modular Smart Array installation and user guide